BacterChrom™ TBX Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection the detection and enumeration of Escherichia coli in foods.
- Code: 01045
- Packaging: 10 plates/box or as per customer requirem ents.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
INTENDED USE
- BacterChrom™ TBX is based on Tryptone Bile Salts Agar medium, used to detect and enumerate E. coli in foods, with the addition of a chromogenic agent, x-ß-D-Glucuronide, to detect the presence of the enzyme glucuronidase, which is highly specific for E. coli.
- The packaging with semi-permeable Cellophane film helps balance the humidity of the environment during storage.
PRINCIPLES
- The released chromophore in BacterChrom™ TBX is colored and target colonies are easily identified. E. coli absorbs the chromogenic agent x-ß-D-glucuronide, and the intracellular glucuronidase enzyme activity breaks the bond between the chromophore and the glucuronide. The released chromophore is colored and builds up within the cells, causing the E. coli colonies to be blue-green colored.
- Casein peptone provides nitrogen, vitamins, minerals and amino acids essential for growth. Bile Salts are inhibitors to other Gram-positive organisms and suppress coliform bacteria. Bacteriological agar is the solidifying agent.
- ISO 16649 specifies a horizontal method for the enumeration of ß-glucuronidase-positive E. coli in products intended for human consumption or for the feeding of animals.
- The negative b-ß-glucuronidase E. coli colonies are colorless, e.g. E. coli O157: H7. The high temperatures (44°C) inhibit the growth of E. coli O157: H7.
- Allow to warm to room temperature before inoculation, dry the plates in an incubator with the covers partially removed.
- Inoculate the BacterChrom™ TBX either by the plating method in depth, seeding on the surface or by the membrane filtration method.
- Incubate the plates for 21 hours at a temperature of 44°C.
RESULTS
- Calculate the number of positive Escherichia coli ß-glucuronidase colonies from the number of typical blue colonies.
BacterLab ensures the quality of each product batch by testing with ATCC reference strains.
| Reference strains | Incubation conditions | Expected results |
| E. faecalis ATCC 29212 | Incubate for 21 ± 3 hours at 44 ± 1°C | Inhibited |
| E. coli ATCC 35218 | PR ≥ 50% |
For 1 liter of medium
| Casein enzymatic digest | 20,0 g |
| Bile salts n°3 | 1,5 g |
| BCIG (5-bromo-4-chloro-3-indolyl β-D-glucuronate) | 0,075 |
| Bacteriological agar | 15,0 g |
pH of the ready-to-use medium at 25°C: 7,2 ± 0,2
*Note: This ingredient is for reference only our company will formulate the ingredient according to requests or tender specifications.
| Product Name | Code | Packaging |
| BacterChrom™ TBX | 01045 | 10 plates/box or as per customer request. |
Related products
BacterContact™ Sabouraud CAF Agar + Penase + Cephalosporinase + Neutralizing
- Ready-to-use medium on 60mm plates for enumeration of yeasts and moulds on sanitized surface and personnelwith inactivation of β-lactam antibiotics and disinfectants.
- Code: 4109024
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 06 months from the date of manufacture.
SwabCollect™ Cary Blair with Charcoal, 5mL
- Recommended for collection and shipment of clinical specimens.
- Code: 4106009
- Packaging: 50 set/box or customer request.
- Storage Conditions: 4 – 25°C.
- Transportation: Ambient temperature.
- Shelf Life: 18 months from the date of manufacture.
BacterChrom™ Yeast, Mold Agar
- Ready to use chromogenic medium on 90mm plates or quantifying yeasts and molds in food and water.
- Code: 01001
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterChrom™ Staphylococcus Agar Plates
- Ready-to-use chromogenic medium on 90mm plates for isolating Staphylococcus spp. in industrial products, veterinary samples, and environmental samples.
- Code: 01019
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterContact™ Sabouraud Dextrose Agar + Neutralizing
- BacterContact™ Sabouraud Dextrose Agar + Neutralizing
- Code: 4109027
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 06 months from the date of manufacture.
SwabCollect™ D/E Neutralizing Broth, 1 mL
- Microbial Sampling Tool for surface sampling, using a swab and a plastic tube containing D/E Neutralizing Broth to recover and protect microorganisms, during transport and analysis.
- Code: 4108029
- Packaging: 50 set/box or customer request.
- Storage Conditions: 4 – 25°C.
- Transportation: Ambient temperature.
- Shelf Life: 18 months from the date of manufacture.
SwabCollect™ Buffered Peptone Water, 1 mL
- Microbial Sampling Tool for surface sampling, using a swab and a plastic tube containing BPW (Buffered Peptone Water) to recover and protect microorganisms during transport and analysis
- Code: 4108001
- Packaging: 50 set/box or customer request.
- Storage Conditions: 4 – 25°C.
- Transportation: Ambient temperature.
- Shelf Life: 18 months from the date of manufacture.
BacterContact™ Tryptic Soy Agar + 0.1% Penase + Neutralizing
- Ready-to-use medium on 60mm plates for environmental and personnel monitoring with inactivation of penicillins and disinfectants.
- Code: 4109028
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 06 months from the date of manufacture.
BacterChrom™ Listeria Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection and numeration of Listeria monocytogenes
- Code: 01029
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
SwabCollect™ Maximum Recovery Diluent, 4 mL
- Microbial Sampling Tool for surface sampling, using a swab and a plastic tube containing Maximum Recovery Diluent to recover and protect microorganisms, during transport and analysis.
- Code: 4108034
- Packaging: 50 set/box or customer request.
- Storage Conditions: 4 – 25°C.
- Transportation: Ambient temperature.
- Shelf Life: 18 months from the date of manufacture.

Vn