BacterChrom™ Candida Plus Agar Plates
- Ready to use 90mm chromogenic medium for detecting and differentiating the main clinical Candidaspecies, including C.auris.
- Code: 01005
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
INTENDED USE
- BacterChrom™ Candida Plus Agar is a selective chromogenic culture medium intended for use in the qualitative direct detection, differentiation and presumptive identification of Candida species including C. auris.
- The packaging with semi-permeable Cellophane film helps balance the humidity of the environment during storage.
PRINCIPLES
- BacterChrom™ Candida Plus Agar is designed to distinguish microorganisms based on specific enzymatic activities that generate unique colony colors. This differentiation allows for easy visual identification and classification of various species. The medium selectively inhibits unwanted growth while promoting the development of target microorganisms, ensuring high specificity and reducing background interference.
- Allow to warm to room temperature before inoculation, dry the plates in an incubator with the covers partially removed.
- Direct streaking sample onto the plate
- Incubate in aerobic conditions at 35 – 37°C for 24 – 48 hour
RESULTS
- Qualitative reading and interpretation of the plates:
| Microorganism | Typical colony apprearance |
| C. albicans | green-blue |
| C. auris | light blue with blue halo, blue from the back side of the plate |
| C. tropicalis | metallic blue with pink halo |
| C. krusei | pink and fuzzy |
| C. glabrata | mauve |
| Bacteria | mostly inhibited |
BacterLab ensures the quality of each product batch by testing with ATCC reference strains.
| Reference strains | Incubation conditions | Expected results |
| C. albicans ATCC 60193 | Incubate for 24 – 48 hours at 35 – 37 °C | Blue colonies |
| C. auris ATCC MYA-5001 | Light blue colonies with a blue halo | |
| C. tropicalis ATCC 1369 | Metallic blue colonies with a pink halo. | |
| C. krusei ATCC 14243 | Colonies with a light pink center | |
| C. glabrata ATCC 2001 | Light purple colonies | |
| E. coli ATCC 25922 | Inhibited |
For 1 liter of medium
| Agar | 15,0 g |
| Peptone | 11,0 g |
| Chromogenic and selective mix | 24,9 g |
pH of the ready-to-use medium at 25°C: 6,1 ± 0,2
*Note: This ingredient is for reference only our company will formulate the ingredient according to requests or tender specifications.
| Product Name | Code | Packaging |
| BacterChrom™ Candida Plus Agar | 01005 | 10 plates/box or as per customer request. |
Related products
BacterChrom™ Pasteurella Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection of Pasteurellaceae
- Code: 01035
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterPlate™ Blood Agar with Nalidixic Acid (BANg)
- Ready-to-use medium on 90mm plates for the selective culture of Staphylococcus and Streptococcus. Differentiation of α, β, and ɤ hemolytic phenotypes.
- Code: 05005
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
Horizontal Laminar Flow Cabinet, HUYAir HLF
The Horizontal Laminar Flow Cabinet, HUYAir HLF designed to be used with non-hazardous and easily accessible materials within the working area. The distinctive feature of this HLF cabinet is to create a clean working environment within a specified range, widely applicable for cleaning the working area and internal components of the cabinet during operations, with a digital LCD control system.
- Complies with standards: NSF 49, EN 12469.
- The cabinet is certified by the National Institute of Hygiene and Epidemiology.
- Size standard: 900mm | 1200mm | 1500mm | 1800mm.
- Warranty: 03 years.
BacterChrom™ Enterobacteria Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection and enumeration of Enterobacteriaceae
- Code: 01033
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterChrom™ Malassezia Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection of Malassezia spp.
- Code: 01036
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterPlate™ Chocolate Agar with Neomycin
- Ready – to – use medium for culturing fastidious microorganisms, particularly Neisseria and Haemophilus.
- Code: 05016
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterChrom™ CCA Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection and enumeration of E. coli and coliform bacteria in water according to the ISO 9308-1 norm.
- Code: 01044
- Packaging: 10 plates/box or as per customer requirem ents.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterPlate™ Blood Agar with Gentamycin (BAGe)
- Ready-to-use medium on 90mm plates for the selective culture of Streptococcus. Differentiation of α, β, and ɤ hemolytic phenotypes.
- Code: 05006
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterPlate™ Chocolate Agar with Multivitox
- Medium for culturing fastidious microorganisms, particularly Neisseria and Haemophilus.
- Code: 05017
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
Vertical Laminar Flow Cabinet, HUYAir VLF
The HUYAir VLF is a series of highly efficient Vertical Laminar Flow (VLF) Microbiological Safety Cabinets designed to protect samples, equipment, and other components in the work area from molecular to highly sensitive applications. It is ideal for use with non-hazardous and easily accessible materials in the work area as desired. The key feature of the VLF cabinets is to create a clean working environment for a wide range of applications and utilize UV lamps for sterilization, cleaning the work area, and internal components during operation with the LCD digital control system.
- Complies with standards: NSF 49, EN 12469.
- The cabinet is certified by the National Institute of Hygiene and Epidemiology.
- Size standard: 900mm | 1200mm | 1500mm | 1800mm
- Warranty: 03 years.