BacterChrom™ CCA Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection and enumeration of E. coli and coliform bacteria in water according to the ISO 9308-1 norm.
- Code: 01044
- Packaging: 10 plates/box or as per customer requirem ents.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
INTENDED USE
- BacterChrom™ CCA is a selective chromogenic medium designed for the detection and enumeration of ß-glucuronidase-positive E. coli and coliforms in water samples with low bacterial background flora. It is particularly suited for applications requiring compliance with ISO 9308-1 standards, ensuring safe water quality monitoring for human consumption, including drinking water, pool water, and treated water samples.
- The packaging with semi-permeable Cellophane film helps balance the humidity of the environment during storage.
PRINCIPLES
- Coliforms, Enterobacteriacae able to ferment lactose (lactose positive Enterobacteriacae), are bacteria present not only in human and warm blooded animals intestinal flora but also in the soil and water. Coliforms are proof of organic, environmental or faecal contamination. Faecal contamination, due to coliforms coming from animal waste, consists mainly of Escherichia coli and thermotolerant Klebsiella. Strict regulations exist for E. coli/coliform presence in water samples. This can be explained by the importance of these germs in determining drinking water safety and process efficiency of treatment, storage and distribution.
- BacterChrom™ CCA contains chromogenic substrates that interact with specific enzymatic activities of target organisms, producing distinct colony colors for differentiation. Selective agents are incorporated to suppress non-target organisms, ensuring high specificity and accuracy. This formulation simplifies the identification and enumeration of coliforms and E. coli, supporting efficient workflows in microbiological
- Allow to warm to room temperature before inoculation, dry the plates in an incubator with the covers partially removed.
- Asseptically filter the water sample through a 0.45 μm nitrocellulosic (or equivalent) membrane.
- Place the membrane on the BacterChrom™ CCA
- Turn upside down the plate and incubate in aerobic conditions at 36 ± 2°C for 18 – 24 hours
RESULTS
- Qualitative reading and interpretation of the plates:
Microorganism | Typical colony apprearance |
E. coli | metallic blue to violet |
Other coliform bacteria | pink to red |
Other Gram (-) bacteria | colorless |
BacterLab ensures the quality of each product batch by testing with ATCC reference strains.
Reference strains | Incubation conditions | Expected results |
P. aeruginosa ATCC 9027 | Incubate for 24 hours at 37°C | Good growth |
K. aerogenes ATCC 13048 | PR ³ 70% | |
E. coli ATCC 35218 | PR ³ 70% |
For 1 liter of medium
Peptone yeast | 3,0 g |
Sodium dihydrogen phosphate | 2,2 g |
Agar | 14,9 g |
NaCl | 5,0 g |
Disodium hydrogen phosphate | 2,7 g |
Sodium pyruvate | 1,0 g |
Tryptophan | 1,0 g |
Sorbitol | 1,0 g |
Tergitol | 0,15 g |
Chromogenic mix | 0,5 g |
pH of the ready-to-use medium at 25°C: 6,8 ± 0,2
*Note: This ingredient is for reference only our company will formulate the ingredient according to requests or tender specifications.
Product Name | Code | Packaging |
BacterChrom™ CCA | 01044 | 10 plates/box or as per customer request. |
Related products
BacterChrom™ Y.enterocolitica Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection and differentiation of pathogenic Yersinia enterocolitica strains
- Code: 01038
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
Ducted Fume Hood, HUYAir FH
The Ducted Fume Hood, HUYAir FH used to control and treat pollutant emissions in industrial and chemical applications, particularly when working with strong acids and corrosive chemicals, to protect the health of workers.
- The quality of the Toxic Fume Hood, HUYAir FH, meets the ASHRAE 110 standard.
- Size standard: 1200mm | 1500mm | 1800mm.
- Warranty: 3 years.
Horizontal Laminar Flow Cabinet, HUYAir HLF
The Horizontal Laminar Flow Cabinet, HUYAir HLF designed to be used with non-hazardous and easily accessible materials within the working area. The distinctive feature of this HLF cabinet is to create a clean working environment within a specified range, widely applicable for cleaning the working area and internal components of the cabinet during operations, with a digital LCD control system.
- Complies with standards: NSF 49, EN 12469.
- The cabinet is certified by the National Institute of Hygiene and Epidemiology.
- Size standard: 900mm | 1200mm | 1500mm | 1800mm.
- Warranty: 03 years.
BacterPlate™ Blood Agar
- Ready-to-use medium on 90mm plates for culturing and differentiating hemolytic phenotypes α, β, and ɤ.
- Code: 05004
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 04 months from the date of manufacture.
BacterPlate™ Chocolate Agar with Neomycin
- Ready – to – use medium for culturing fastidious microorganisms, particularly Neisseria and Haemophilus.
- Code: 05016
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterChrom™ AOLA Plates
- Ready-to-use chromogenic medium on 90mm plates for the detection, enumeration and isolation of Listeria monocytogenes and Listeria spp.
- Code: 01046
- Packaging: 10 plates/box or as per customer requirem ents.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
Powder Weighing Balance Enclosures, HUYAir PWB
HUYlab’s Powder Weighing Balance Enclosures provides protection for users during the weighing, measuring, pouring, mixing, and other related activities involving dust, particles, and powders of hazardous compounds and/or liquid chemicals.
- Complies with standards: NSF 49, EN 12469.
- The cabinet is certified by the National Institute of Hygiene and Epidemiology.
- Size standard: 700mm | 900mm | 1200mm | 1500mm.
- Warranty: 03 years.
BacterChrom™ Cronobacter Plates
- Ready-to-use chromogenic medium on 90mm plates for isolating Cronobacter bacteria according to ISO 22964 standards.
- Code: 01043
- Packaging: 10 plates/box or as per customer requirem ents.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterChrom™ Streptococcus Plates
- Ready-to-use chromogenic medium on 90mm plates for the isolation and differentiation of Streptococcus spp.
- Code: 01037
- Packaging: 10 plates/box or as per customer requirements.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.
BacterPlate™ Chocolate Agar with VTCN (HP VTCN)
- Ready-to-use medium on 90mm plates supplemented with VTCN for the selective culture of Helicobacter pylori
- Code: 05012
- Packaging: 10 plates/ box or as per customer request.
- Storage Conditions: 2–8°C.
- Transportation: Ambient temperature.
- Shelf Life: 03 months from the date of manufacture.